How to cut > How to preheat before thermal cutting

Preheating temperature recommendations

Hardox® wear plate
Hardox® wear plate
 Hardox® HiAce
Plate thickness
 - 40 mm
Minimum preheating temperature
 No Preheating
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® HiAce
Plate thickness
 40,0-50 mm
Minimum preheating temperature
 100°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® HiAce
Plate thickness
 50,0-70 mm
Minimum preheating temperature
 150°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® HiAce
Plate thickness
 70,0-100 mm
Minimum preheating temperature
 175°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® HiTemp
Plate thickness
 5,0-51 mm
Minimum preheating temperature
 No Preheating
Max temperature
 500°C
Hardox® wear plate
Hardox® wear plate
 Hardox® HiTuf
Plate thickness
 - 90 mm
Minimum preheating temperature
 No Preheating
Max temperature
 300°C
Hardox® wear plate
Hardox® wear plate
 Hardox® HiTuf
Plate thickness
 90,0-150 mm
Minimum preheating temperature
 100°C
Max temperature
 300°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 400
Plate thickness
 - 45 mm
Minimum preheating temperature
 No Preheating
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 400
Plate thickness
 45,0-60 mm
Minimum preheating temperature
 100°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 400
Plate thickness
 60,0-80 mm
Minimum preheating temperature
 150°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 400
Plate thickness
 81,1-150 mm
Minimum preheating temperature
 175°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 450
Plate thickness
 - 40 mm
Minimum preheating temperature
 No Preheating
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 450
Plate thickness
 40,0-50 mm
Minimum preheating temperature
 100°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 450
Plate thickness
 50,0-70 mm
Minimum preheating temperature
 150°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 450
Plate thickness
 70,0-150 mm
Minimum preheating temperature
 175°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 500 Tuf
Plate thickness
 4,0-25 mm
Minimum preheating temperature
 No Preheating
Max temperature
 225?°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 500
Plate thickness
 - 25 mm
Minimum preheating temperature
 No Preheating
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 500
Plate thickness
 25,0-50 mm
Minimum preheating temperature
 100°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 500
Plate thickness
 50,0-60 mm
Minimum preheating temperature
 150°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 500
Plate thickness
 60,0-150 mm
Minimum preheating temperature
 175°C
Max temperature
 225°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 550
Plate thickness
 - 20 mm
Minimum preheating temperature
 No Preheating
Max temperature
 200°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 550
Plate thickness
 20,0-51 mm
Minimum preheating temperature
 150°C
Max temperature
 200°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 550
Plate thickness
 51,1-150 mm
Minimum preheating temperature
 175°C
Max temperature
 200°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 600
Plate thickness
 - 12 mm
Minimum preheating temperature
 No Preheating
Max temperature
 180°C
Hardox® wear plate
Hardox® wear plate
 Hardox® 600
Plate thickness
 12,0-65 mm
Minimum preheating temperature
 170°C
Max temperature
 180°C
Hardox® wear plate
Hardox® wear plate
 Hardox® Extreme
Plate thickness
 8,0-19 mm
Minimum preheating temperature
 100°C
Max temperature
 100°C

Minimum and maximum preheating temperatures for Hardox® wear plates

Grade
Grade
Strenx® 700
Plate thickness
 ≤ 80 mm
Min. preheating temp. (C°)
 No preheating
Max. preheating temp. (C°)
 300
Grade
Grade
Strenx® 900
Plate thickness
 > 80 mm
Min. preheating temp. (C°)
 150
Max. preheating temp. (C°)
 300
Grade
Grade
Strenx® 960
Plate thickness
 ≤ 30 mm
Min. preheating temp. (C°)
 150
Max. preheating temp. (C°)
 150
Grade
Grade
Strenx® 1100
Plate thickness
 > 30 mm
Min. preheating temp. (C°)
 150
Max. preheating temp. (C°)
 150

Minimum and maximum preheating temperatures for Strenx®.

Steel
Steel
 Toolox® 33
Preheating
Min. preheat/ interpass temperatur [°C]
 150
Preheating
Max. preheat/ interpass temperatur [°C]
 580
Steel
Steel
 Toolox® 44
Preheating
Min. preheat/ interpass temperatur [°C]
 225
Preheating
Max. preheat/ interpass temperatur [°C]
 580

Minimum and maximum preheating temperatures for Toolox®

Armox® 370T CL1 & CL2
Armox® 370T CL1 & CL2
 Up to 15 mm
Armox® 440
 Up to 25 mm
Armox® 500T
 Up to 15 mm
Armox® 600T
 Up to 10 mm
Armox® Advance
 -
Recommended cutting method

Abrasive waterjet
Plasma
Laser
Abrasive disc

Armox® 370T CL1 & CL2
Armox® 370T CL1 & CL2
 15-25 mm
Armox® 440
 25-30 mm
Armox® 500T
 15-25 mm
Armox® 600T
 10-20 mm
Armox® Advance
 -
Recommended cutting method
Abrasive waterjet
Laser
Gas cutting at reduced speed
Gas cutting plus preheating to 170 ± 30°C
Abrasive disc 
Armox® 370T CL1 & CL2
Armox® 370T CL1 & CL2
 40-60 mm
Armox® 440
 25-30 mm
Armox® 500T
 40-60 mm
Armox® 600T
 -
Armox® Advance
 -
Recommended cutting method
Abrasive waterjet
Gas cutting plus preheating to 170 ± 30°C plus keep warm for 4 hours at 160 ± 40°C
Abrasive disc
Armox® 370T CL1 & CL2
Armox® 370T CL1 & CL2
 Above 60 mm
Armox® 440
-
Armox® 500T
 Above 60 mm
Armox® 600T
 -
Armox® Advance
 Up to 12 mm
Recommended cutting method
Abrasive waterjet
Abrasive disc

Recommended cutting method for Armox®

Contact Technical support


The information in this report is only applicable to SSAB’s products and should not be applied to any other products than original SSAB products. 


This report provides general results and recommendations for SSAB steel products. This report is subject to SSAB’s Terms of Use. It shall be the user's responsibility to verify that the information contained herein is correct and is suitable to be used for the particular purpose and application of the user. The report is intended to be used by professional users only who possess adequate expertise, qualification and knowledge for the safe and correct use of the results and recommendations in this report. This report is provided “as is”. The use of the report is at user’s own discretion and risk and that users will be solely responsible for any use of this report. SSAB disclaims any liability for the content or potential errors of this report, including but not limited to warranties and condition of merchantability or fitness for a particular purpose or suitability for individual applications. SSAB shall not be liable for any kind of direct or indirect damages and/or costs related to or arising therefrom, whether special, incidental, consequential or directly or indirectly related to the use of, or the inability to use, the report or the content, information or results included therein.