180

You are currently visiting the SSAB group site

To go to your country specific site please follow this link:

banner infrastructure
Combi wall

Combi wall

Retaining wall structures based on steel piles

Retaining wall structures based on steel piles are often the best solution to replace traditional, labor-intensive cast-in-place based retaining wall structures.

RR® large diameter piles can be built into a continuous combi wall by welding interlocking sections or complete sheet piles into them. In a combi wall, piles act as the load-bearing structure, while sheet piles installed in between make the wall continuous.

Thanks to SSAB’s high-grade steel, our combi walls have excellent bending stiffness and resistance.


Applications:

  • Retaining wall structures
  • Building foundations
  • Wharves and piers
  • Road and railway structures
  • Bridges


Standard pile sizes used in Combi walls. For project specific dimensions, please contact our sales.

Standard piles and availability of steel grades of Combi pile wall


Wall thickness [mm]

8
10 12.5
14.2
16
18
20
22
23
RD400 X
X X





RD450 X
X
X
           
RD500 X X X X
*



RD550 X X X X
*        
RD600 X X X X X O



RD650 X X X X X O
     
RD700 X X X X X X O


RD750 X X X X X X O
   
RD800 X X X X X X O *
RD900   X X X X X O *
RD1000   X X X X X O * *
RD1200   X X X X X O * *

  X = Steel grades S355J2H, S440J2H and S550J2H          O = Steel grades S355J2H and S440J2H

*) Please contact our sales for availability