LR A/B/D/E

Download data sheet

General Product Description

Lloyd’s Register Grades A, B, D, and E are normal-strength structural steels with a minimum specified yield strength of 34 ksi and specified minimum Charpy V-notch impact toughness properties.

Applications

Typical applications include ships and other structural applications.

Available Dimensions

Grade
Grade
Grade A
Product type
Plate
Thickness
(inmm)
0.1875 - 2.004.762 - 50.8
Width
(inmm)
72 - 1201800 - 3050
Length
(inmm)
240 - 10206100 - 25910
Grade
Grade
Grade B
Product type
Plate
Thickness
(inmm)
0.1875 - 2.004.762 - 50.8
Width
(inmm)
72 - 1201800 - 3050
Length
(inmm)
240 - 10206100 - 25910
Grade
Grade
Grade D
Product type
Plate
Thickness
(inmm)
0.1875 - 1.384.762 - 35.1
Width
(inmm)
72 - 1201800 - 3050
Length
(inmm)
240 - 10206100 - 25910
Grade
Grade
Grade E
Product type
Plate
Thickness
(inmm)
0.1875 - 2.954.762 - 74.9
Width
(inmm)
60 - 131.91500 - 3350
Length
(inmm)
73 - 5901900 - 15000

Width: Please inquire for plate widths less than 72 in. and inquire plate product over 120 in.

Length: Please inquire for plate lengths outside the noted ranges.

Thickness: Please inquire for plate thicknesses outside the noted ranges.

Mechanical Properties

Tensile testing is performed in the transverse direction.

Grade
Grade
Grade A
Thickness
(inmm)
0.1875 - 2.004.762 - 50.8
Yield strength
(min ksi)
34
Tensile strength
(ksi)
58 - 75
Elongation A5 1)
(min %)
22
Grade
Grade
Grade B
Thickness
(inmm)
0.1875 - 2.004.762 - 50.8
Yield strength
(min ksi)
34
Tensile strength
(ksi)
58 - 75
Elongation A5 1)
(min %)
22
Grade
Grade
Grade D
Thickness
(inmm)
0.1875 - 1.384.762 - 35.1
Yield strength
(min ksi)
34
Tensile strength
(ksi)
58 - 75
Elongation A5 1)
(min %)
22
Grade
Grade
Grade E
Thickness
(inmm)
0.1875 - 2.954.762 - 74.9
Yield strength
(min ksi)
34
Tensile strength
(ksi)
58 - 75
Elongation A5 1)
(min %)
22

1) See Lloyd’s Register Rules for elongation requirements for alternative tensile specimens.

Impact Properties

Grade
Grade
Grade B
Thickness
(inmm)
0.1001 - 2.002.543 - 50.8
Test temperature
(°F)
32
Min Longitudinal Average Energy 1)
(ft-lbs)
20
Min transverse average energy 1)
(ft-lbs)
15
Grade
Grade
Grade D
Thickness
(inmm)
0.1875 - 1.384.762 - 35.1
Test temperature
(°F)
-4
Min Longitudinal Average Energy 1)
(ft-lbs)
20
Min transverse average energy 1)
(ft-lbs)
15
Grade
Grade
Grade E
Thickness
(inmm)
0.1875 - 1.974.762 - 50.0
Test temperature
(°F)
-40
Min Longitudinal Average Energy 1)
(ft-lbs)
20
Min transverse average energy 1)
(ft-lbs)
15
Grade
Grade
Grade E
Thickness
(inmm)
1.98 - 2.7550.3 - 69.8
Test temperature
(°F)
-40
Min Longitudinal Average Energy 1)
(ft-lbs)
25
Min transverse average energy 1)
(ft-lbs)
18
Grade
Grade
Grade E
Thickness
(inmm)
2.76 - 2.9570.1 - 74.9
Test temperature
(°F)
-40
Min Longitudinal Average Energy 1)
(ft-lbs)
30
Min transverse average energy 1)
(ft-lbs)
20

1) Tests are to be taken in the longitudinal direction. Normally, transverse test specimens are not required unless otherwise specified in the order. Generally, impact tests are not required when material thickness is less than 0.236 in.

No more than one value below the specified minimum average energy but no less than 70% of the specified minimum average energy value.

Minimum average energy for full-size specimens. Refer to Lloyd’s Register Rules for sub-size specimen energy requirements.

Show specs in: