Docol® 800CP complex phase

More about complex phase steel

Download data sheet

Select Language

Get datasheet by email
Close

Get datasheet by email

Sur cette page

General Product Description

Docol 800CP is intended for designs where high structural strength and energy absorption are desired, suitable for cold formed safety components and crash-relevant equipment within the automotive and transport industries.

Dimension Range

Cold rolled / UC: thickness 0.50-2.10 mm, width up to 1527 mm.

Cold rolled / GI, GA, ZA: thickness 0.80-2.50 mm, width up to 1460 mm.

Hot rolled / UC: thickness 2.00-4.00 mm, width up to 1500 mm.

Hot rolled / GI: thickness 2.00-3.50 mm, width up to 1400 mm.

Slit strip and cut to length sheets are available upon request.

Grade and coating specific restrictions on available dimensions may occur.

Mechanical Properties

Hide/Show specific columns Edit
Select columns to display
    Standard Coating Test direction
    Yield strength Rp0.2
    (MPa)
    Tensile strength Rm
    (MPa)
    Elongation A80
    (min %)
    Elongation A5
    (min %)
    BH2
    (min MPa)
    Hole expansion ratio 2)
    (min %)
    Hole expansion ratio 2)
    (% typical)
    Docol CR​570Y​780T-​CP VDA 239-100 UC, GI, GA*, ZA* L 570 - 720 780 - 920 10 1) 30
    Docol HR​660Y​760T-​CP VDA 239-100 UC, GI L 660 - 820 760 - 960 10 13 30
    Docol HR800HER-75 SSAB UC, GI L 660 - 820 760 - 960 11 14 30 45 75
    Docol HR800HER-100 SSAB UC L 660 - 820 760 - 960 12 15 30 65 100
    Docol Roll 800 SSAB UC T 600 - 750 800 - 950 10
    Compare parameters

    Select one parameter to compare

    Comparison

      *Available upon request.

      1) For GA coatings the minimum elongation value is reduced by 2 units.

      2) HER –ratio is average of three test results out of five tested samples by excluding minimum and maximum results.

      Chemical Composition (ladle analysis)

      Hide/Show specific columns Edit
      Select columns to display
        Coating C
        (max %)
        Si
        (max %)
        Mn
        (max %)
        P
        (max %)
        S
        (max %)
        Al
        (%)
        Nb+Ti
        (max %)
        Cr+Mo
        (max %)
        B
        (max %)
        Cu
        (max %)
        Docol CR​570Y​780T-​CP UC, GI, GA*, ZA* 0.18 1.00 2.50 0.050 0.010 0.015 - 1.00 0.15 1.00 0.005 0.20
        Docol HR​660Y​760T-​CP UC, GI 0.18 1.00 2.20 0.050 0.010 0.015 - 1.2 0.25 1.00 0.005 0.20
        Docol HR800HER-75 UC, GI 0.18 1.00 2.20 0.050 0.010 0.015 - 1.2 0.25 1.00 0.005 0.20
        Docol HR800HER-100 UC 0.18 1.00 2.20 0.050 0.010 0.015 - 1.2 0.25 1.00 0.005 0.20
        Docol Roll 800 UC 0.16 0.40 1.80 0.020 0.010 From 0.015 0.10
        Compare parameters

        Select one parameter to compare

        Comparison

          * Available upon request.

          Tolerances

          Cold rolled (UC): Tolerances in accordance to EN 10131.

          Hot rolled (UC): Tolerances in accordance to EN 10051.

          Hot-dip galvanized (GI, GA, ZA): Tolerances in accordance to EN 10143.

          Customized dimensional and shape tolerances are available upon request.

          Coatings

          The metal coating options for Docol products include:

          Hot-dip zinc coating (GI) consists almost entirely of zinc (>99%). It is lead free, resulting in a small zinc spangle size. The coating provides good corrosion protection.

          Galvannealed coating (GA) is a zinc-iron alloy coating having an iron content of approximately 10%. Galvannealed is produced by post-heat treatment in continuous hot-dip coating process. Galvannealed provides excellent resistance weldability and corrosion protection of painted products.

          Galfan coating (ZA) is a zinc-aluminium alloy coating having the eutectic composition approximately of 95% Zn and 5% Al. Galfan is produced in continuous hot-dip coating process. Galfan has better anticorrosive and forming properties than conventional hot-dip zinc coating (GI).

          Electrogalvanized coating (EG) is applied continuously by electro deposition. The coating consists of zinc (>99%). Electrogalvanized steel is characterized by its excellent surface quality and uniform coating thickness.

          Grade specific availability of metal coatings for Docol products is given in the Mechanical properties table (Coating).

          Hide/Show specific columns Edit
          Select columns to display
            Coating type Coating class Standard Closest in EN 10346, informative Coating mass per side, single spot test (g/m2) Thickness per side informative (µm)
            GI 40/40 VDA 239-100 Z100 40 - 60 1) 5.6 - 8.5
            GI 50/50 VDA 239-100 50 - 70 1) 7.0 - 9.9
            GI 60/60 VDA 239-100 Z140 60 - 90 8.5 - 12.7
            GI 70/70 VDA 239-100 70 - 100 9.9 - 14.1
            GI 85/85 VDA 239-100 85 - 115 12.0 - 16.2
            GI 115/115 VDA 239-100 Z275 115 - 155 16.2 - 21.8
            GA 40/40 VDA 239-100 ZF100 40 - 60 1) 5.6 - 8.5
            GA 50/50 VDA 239-100 ZF120 50 - 80 7.0 - 11.3
            ZA 95 EN 10346 ZA95 7.0 -
            ZA 130 EN 10346 ZA130 10.0 -
            EG 25/25 EN 10152 12 - 1.7 -
            EG 50/50 EN 10152 29 - 4.1 -
            EG 75/75 EN 10152 47 - 6.6 -
            EG 100/100 EN 10152 65 - 9.1 -
            Compare parameters

            Select one parameter to compare

            Comparison

              Docol metal coated products are available with surface quality for unexposed applications.

              In addition to these coating masses, OEM specific coatings and single sided EG coatings are available upon request.

              1) For hot-dipped (GI, ZA, GA) hot rolled (HR) grades, the coating mass tolerance is increased to 30 g/m² by increasing the upper limit.

              Surface Treatments

              Uncoated (UC): available as oiled.

              Hot-dip galvanized (GI, GA, ZA): available as oiled and/or chemically passivated.

              Electrogalvanized (EG): available as oiled and/or chemically passivated or phosphated.

              All surface treatments are in accordance with RoHS directive (2011/65/EU) and do not contain Chromium VI (Cr6+). Surface treatments provide only temporary surface protection during transportation and storage. In order to avoid corrosion damages, care must be taken to keep the products dry during transportation and storage. If they become wet, they must be separated and situated so that they are dried quickly.

              Fabrication and Other Recommendations

              For information concerning fabrication, see SSAB´s brochures on www.ssab.com or consult Tech Support.

              Appropriate health and safety precautions must be taken when bending, welding, cutting, grinding or otherwise working on the products.

              Docol® Complex Phase steel product offer

              Docol® 600 CP complex phase

              Docol® 800CP complex phase

              Docol® 1000CP complex phase

              Docol® 1200CP complex phase

              Autres sujets dans la même veine